MDE e-Permits

Permit Number: MDRCD09SY
State Number: 20CPD09SY

Notice for Stormwater Associated with Construction Activity

Notice of Intent information is shown below.

Stormwater Pollution Prevention Plan » Show » Hide

There are NO Federal or State listed rare, threatened, and endangered species and/or designated critical habitats that are located in the project area.


Option 1. All operators associated with a construction site under this permit must develop a SWPPP consistent with the requirements in Part III.F prior to their submittal of the NOI.


C. I plan on implementing controls associated with the activities requiring pollution prevention measures, referenced in Part III.A.3 of the permit.

  • For equipment and vehicle fueling and maintenance
  • For equipment and vehicle washing
  • For storage, handling, and disposal of building products, materials, and wastes
  • For the application of fertilizers

D. I am a co-permittee/co-operator with one or more operators, but not in a common plan.

Erosion and Sediment Control » Show » Hide

Erosion and Sediment Control Plan Approval Authority: Baltimore County SCD

Plan ID Number: 118-17K9-24

General Information » Show » Hide

Permit Type: General Permit


Signatory

Name: Mr.  William   McGrew

Organization: Highland Turf Inc. t/a HTI Contractors


Address: 4539 Sykesville Road, Finksburg, Maryland 21048

Mailing Address: 4539 Sykesville Road, Finksburg, Maryland 21048


Phone: 410-781-0155

Email: wmcgrew@hticontractors.net


Permittees

Organization Name Email Address Type
Highland Turf Inc. t/a HTI Contractors William McGrew wmcgrew@hticontractors.net Primary

Contact Person

Name:   Kerrie  Melhorn

Phone: (717) 781-7797

Email: kmcgrew@hticontractors.net


Tax Information

Tax Entity: Corporation/LLC

Site Information » Show » Hide

Site/Project Name: Becker Property

Address: 12001 Falls Road, Cockeysville, Maryland 21217

County: Baltimore City

Site Coordinates (N, W): 39.45698°,  -76.69229°

Total Site Area: 19.00 acres

Total Disturbed Area: 14.34 acres


Site Contact Person

Name:   Shane  Newman

Phone: (410) 977-8137

Email: snewman@hticontractors.net

Project Information » Show » Hide

Construction Project

Project Start Date: 09/15/2025

Project End Date: 09/30/2026

Description: Part of a larger development that had a previously completed phase. Limited to 6 units.

Emergency-related project: No

Located within a floodplain: No

Located within a critical area: No

Types of Construction: Single-Family Residential


Discharge Information

Site Runoff: Surface waters -- Loch Raven Reservoir

Watershed Basin Code: 02130805

Does the site fall within a Tier II Watershed? No

Are the receiving waters listed on the current Maryland 303(d) list as impaired? Yes

Cause(s) of the impairment: Bacteria, Ions, Nutrients, Stream Modification

Use Class: Use III-P


Permanent Stormwater Management Facilities

Stormwater management facilities waived or exempted? No

Documents for Upload » Show » Hide
Document Type Document Name / Link Date Modified
Vicinity Map 14746_Approved ESC Plan Set.pdf 9/4/2025 4:26:45 PM
Certification of Erosion and Sediment Control Plan Approval 14746_Approved ESC Plan Set.pdf 9/4/2025 4:27:51 PM
Certification » Show » Hide
Full Name Signature Date Person Type Disturbed Acreage
William McGrew 9/4/2025 Primary 14.34
William McGrew 9/4/2025 Primary 14.34
MDE Administrator Comments
Comment Date Reviewed By Reviewer Comment
9/5/2025 m**********y Approved for public notice. Be advised, the NOI has been updated to indicate that the receiving waters are also impaired for stream modification, bacteria & nutrients, and are not impaired for sediments. The site address was also updated to be consistent with the approved ESC plans and provided site coordinates.
9/22/2025 m**********y 20-CP coverage granted. Please review the 20-CP (Part II.A.9) ‘Deadlines for Coverage’ regarding new SWPPP triggering activities and additional operators - all operators must obtain 20-CP permit coverage prior to earth disturbing activities. Any construction activity pollution control measures or monitoring requirements required by MDE LMA or DNR WHS must be included with the SWPPP.